SAMTRON - a trusted name in West & North India region for last two decades in the field of Diesel Generating Sets, headed by its founder chairman Late Shri S. L. Saini, the entire business of Saini Group is looked after & handled by the family members, supported by a 200+ strong team of efficient & dedicated technicians.
Our diesel engines are a class apart, which are highly reilable & fuel - efficient and easy to maintain and are compliant with the latest norms for prime movers to Diesel Generating Sets.
Benefits:
SAMTRON POWER GENERATING SET POWERDED BY ESCORTS & TATA | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
DG Set Model | SE 10 G 12 II | SE 15 G 15 II | SE 20 G 20 II | SE 25 G 25 II | SE 30 G 30 II | SE 40 G 40 II | SE 45 G 40 II | SE 62.5 G 62.5 II | SE 697 TC 14 | SE 697 TC 13 | SE 697 TC 10 | |
Engine Model | G 12 II | G 15 II | G 20 II | G 25 II | G 30 II | G 40 II | G 40 II | G 62.5 II | 697 TC 14 | 697 TC 13 | 697 TC 10 | |
KVA/KW | 7.5/10/12.5 | 15 (12) | 20 (16) | 25 (20) | 30 (24) | 40 (32) | 45 (36) | 62.5 (50) | 82.5 (66) | 100 (80) | 125 (100) | |
Duty | Prime | |||||||||||
Frequency/Speed | 50 Hz / 1500 RPM | |||||||||||
Voltage/No. of Phase | 415 Volts / 3 Phase | |||||||||||
Power Factor | 0.8 | |||||||||||
Governor | Mechanical | Electronic | Electronic | Mechanical | ||||||||
Maker | Escorts | Tata | ||||||||||
BHP | 18 | 22 | 25 | 33 | 43 | 58 | 58 | 88 | 105 | 128 | 156 | |
No. of Cylinders | 2 | 2 | 3 | 3 | 3 | 4 | 4 | 4 | 6 | 6 | 6 | |
Bore X Stroke (mm) | 91x110 | 95x110 | 91x100 | 91x100 | 91x100 | 91x100 | 91x100 | 98x122 | 97x128 | 97x128 | 97x128 | |
Fuel Tank Capacity(Ltr.) | 94 | 100 | 130 | 150 | 180 | 180 | 225 | |||||
Shipping Dim. (L*W*H) | 1500x930x1150 | 2100x930x1395 | 2300x930x1395 | 2400x1030x1470 | 2700x1050x1500 | 2800x1050x1500 | 3250x1200x1650 | 3500x1250x1750 | 3500x1250x1800 | |||
Package Weight (Approximate) | 750 | 850 | 950 | 1050 | 1100 | 1200 | 1250 | 1400 | 1650 | 2000 | 2100 | |
Battery | Exide / Amron | |||||||||||
Alternator | Make | Stamford / Meccalte / LS | ||||||||||
Class of Insulation | Class H | |||||||||||
Ingress Protection | IP 23 | |||||||||||
Voltage Regulation | As Per Ic60034 | |||||||||||
Overload Capacity | 10% overload for 1 Hour in every 12 hours of operation | |||||||||||
Control Panel | Matering | Voltage, Current, Frequency, RPM | ||||||||||
Function | Start / Stop | |||||||||||
Protection | Low lub. Oil pressure, High water temperature, Auto shut down visual & alarm | |||||||||||
Electrical Safeties | Over load & Short circuit | |||||||||||
Location | Inbuilt in Canopy | |||||||||||
**Due to continuous product update, specifications are subject to change without prior notice. |